4 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL

In Stock

CP-8804 is a 4 zones fire alarm control panel, which is the central part of the conventional system, designed for applications requiring smoke detectors, manual call points, Alarm bells, etc. The basic unit offers 1 to 4 zones

Category:

Description

CP-8804 is a 4 zones fire alarm control panel, which is the central part of the conventional system, designed for applications requiring smoke detectors, manual call points, Alarm bells, etc. The basic unit offers 1 to 4 zones

It has 3 groups of sounders. Each zone can connect up to 50 devices. A maximum of 100 devies.The zones and sounders of the fire alarm system can be disabled. All input and output devices are monitored by the control panel and the control panel will automatically disconnect when the zone or sounders are short circuited. The control panel can provide 24VDC/ 300mA power for products that require an additional 24V power supply such as beam detectors, gas detectors etc. The detailed status indicators clearly show the working status of the control panel and provide the first fire alarm and subsequent fire alarm functions. After the control panel sends a fire alarm signal, it can provide up to 120 seconds delay time to confirm whether there is a real fire. In addition, the control panel also provides the mains-lost silence function. Pls note. after configure the mains-lost silence mode, the control panel will no longer sends a fault signal to remind the user when the main power is lost.

 

 

Product Features

• The CP-8804 is a zones control panel.

• Each zone has a maximum capacity of 50 devices.

• It has 3 groups of sounders output circuits each capable of supplying 300mA.

• It has a 24Vdc/300mA auxiliary supply.

• It use a switch mode power supply

• It has a set of fault relay contacts, rated at 0.5A SELV.

• It has the ability to disable any zone and any group of sounders.

• The panel will send a fault signal when there is zone short/open or sounder short/open circuit.

• It has the ability to disconnect the zones and sounders automatically when there is zone short or sounder short circuit, after the short is cleared, the zones and sounders will recover.

• It has the sounder start/stop and delay facility (the delay time is 30-120 seconds in 30 seconds increments).

• It has the first fire alarm and subsequent fire alarm functions.

The indicator of the first fire zone is flashing and the subsequent fire zone is lit.

• It has the mains-lost silence function, after configure the mains-lost silence function, the panel will not send the main power lost fault signal.

Technical Data

Specification Value
Main Power AC220V±15%, 50Hz / AC110V±15%, 60Hz
Zone Voltage 24V ±2V
Number of Zones 1, 2, 4
Zone and Sounder End of Line Resistors 3.9KΩ, 1W
Zone Monitoring Current <4.5mA
Zone Alarm Current >20mA
Zone Short Current >110mA
Battery DC 24V (2 x 12V 2.3Ah or 3.3Ah)
Sounder Alarm Output 3 × 300mA (max)/24VDC
Auxiliary Supply 300mA/24V
One set of fault relay contacts Rated at 0.5A SEL V
Humidity ≤95%RH
Dimensions 290 × 87.5 × 211.5mm
Weight 2100g (without battery)

 