CONVENTIONAL HEAT DETECTOR AH-751

In Stock

The AH-751 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72 standards, local codes, and ordinances.

Category: Brand:

Description

All of the CHLORIDE UK AH-751 series heat detectors meet the requirements of UL521 and EN 54-5 for use in fire alarm signalling systems, which provide fast and reliable response for heat 57°C (135°F) or Rate-of-Rise detection, They are intended for use in 2-wire/4-wire Class A2 supervised zone circuits.

The AH-751 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72 standards, local codes, and ordinances.

AH-388 Series - ranges Includes:

AH751-2 2 wire heat alarm
AH751-2L 2 wire heat alarm with remote LED output
AH751-4 4 wire heat alarm (12/24VDC)
AH751-4B 4 wire heat alarm with Buzzer (12/24VDC)
AH751-4AR 4 wire heat alarm with auto-reset function (12/24VDC)
AH751-4ARB 4 wire heat alarm with auto-reset function and Buzzer (12/24VDC)

 

Product Features

• 2 or wire models
• Advanced detection and discrimination algorithms
• Easy installation and maintenance
• Sleek low-profile housing design
• Durable sensor head, no need for replacement
• SMD circuit board design-satisfactory quality and reliability guaranteed
• N/C (normal/close)-N/O (normal/open)selectable relay output
• AR (Auto Reset) function for security systems.
• Five-year limited warranty

Technical Specifications

Model 2/4 wire Voltage DC Standby Current (Max.) Alarm Current 12/24V Surge Current (Max.) Start-Up Time (Max.) Permissible Current (Max.) Frequency Alarm contact Base model
AH751-2 2 10~33V 45µA 50mA 100µA 30S 80mA 1~3 Seconds — P/N762001
AH751-2L 2 10~33V 45µA 50mA 100µA 30S 80mA 1~3 Seconds — P/N764001
AH751-4 4 12/24V 45µA 30mA 100µA 30S — 1~3 Seconds Form A P/N764001
AH751-4-AR 4 12/24V 45µA 30mA 100µA 30S — 1~3 Seconds Form A / Auto Reset P/N764001
AH751-4-ARB 4 12/24V 45µA 30mA 100µA 30S — 1~3 Seconds Form A P/N764001

 

Product Data

Response Temperature Fixed termperature: 57°C (135°F)
Rate-of-Rise: CLASS 2 (EN54-5); or 8°C/Min (UL521)
Ceiling Spacing 50 foot rating for heat sensor
Reset Voltage less than 1 volt
Alarm Indicator LED continuously emitting red light
Remote Output 25 mA max., diode gate
Temperature Range -10°C to 50°C
Permissible Current 80mA maximum
Humidity 0 to 95% RH, no condensation or icing
Alarm Contact (for 4-wire) NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC
Dimensions 102mm (dia.) x 43mm (ht.) with base
Weight 125g/set with base