CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR AH388
The AH-388 series include 2-wire and 4-wire detectors, which provide fast and reliable responseĀ for photoelectric smoke detection. While the smoke and heat detection circuits operate independently, their outputs being “OR’ connected.
Description
All of the Chloride Uk AH388 series detectors meet the requirements ofĀ UL268 and UL521 (ordinary) and EN54-7 and EN54-5 (A2S) for use in fire alarm signalling systems. They are intended for use in 2-wire/4-wire Class A or B supervised zone circuits. The AH-388Ā series detectors are subject to panel compatibility limits and compliance with correspondingĀ NFPA 72 standards, local codes, and ordinances.
The AH-388 series include 2-wire and 4-wire detectors, which provide fast and reliable responseĀ for photoelectric smoke detection. While the smoke and heat detection circuits operate independently, their outputs being “OR’ connected.
AH-388 Series - ranges Includes:
| AH-388-2 | 2 wire photoelectric smoke alarm |
| AH-388-2L | 2 wire photoelectric smoke alarm with remote LED output |
| AH-388-4 | 4 wire photoelectric smoke alarm (12/24VDC) |
| AH-388-4B | 4 wire photoelectric smoke alarm with Buzzer (12/24VDC) |
| AH-388-4AR | 4 wire photoelectric smoke alarm with auto-reset function (12/24VDC) |
| AH-388-4ARB | 4 wire photoelectric smoke alarm with auto-reset function and Buzzer (12/24VDC) |
Notice: AH-388-4 with 48Vdc available
Product Features
⢠2 or wire models
⢠Advanced detection and discrimination algorithms
⢠Easy installation and maintenance
⢠Sleek low-profile housing design
⢠Durable sensor head, no need for replacement
⢠SMD circuit board design-satisfactory quality and reliability guaranteed
⢠AR (Auto Reset) function for security systems.
⢠Five-year limited warranty
Technical Specifications
| Model | 2/4 wire | Thermal | Voltage DC | Standby Current (Max.) | Alarm Current 12/24V | Surge Current (Max.) | Start-Up Time (Max.) | Permissible Current (Max.) | Frequency | Alarm contact | Base model |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AH-388-2 | 2 | ā | 10~33V | 40µA | 50mA | 80µA | 30S | 80mA | 1~3 Seconds | ā | P/N762001 |
| AH-388-2L | 2 | ā | 10~33V | 40µA | 50mA | 80µA | 30S | 80mA | 1~3 Seconds | ā | P/N764001 |
| AH-388-4 | 4 | ā | 12/24V | 40µA | 30/40mA | 80µA | 30S | ā | 1~3 Seconds | Form A | P/N764001 |
| AH-388-4AR | 4 | ā | 12/24V | 40µA | 30/40mA | 80µA | 30S | ā | 1~3 Seconds | Form A / Auto Reset | P/N764001 |
| AH-388-4B | 4 | ā | 12/24V | 40µA | 30/40mA | 80µA | 30S | ā | 1~3 Seconds | Form A | P/N764001 |
| AH-388-4ARB | 4 | ā | 12/24V | 40µA | 30/40mA | 80µA | 30S | ā | 1~3 Seconds | Form A / Auto Reset | P/N764001 |
Product Data
| Smoke Sensitivity | 0.08~0.14db/m(EN standard) or 0.98~2.40%/FT Obscuration (UL standard) |
| Reset Voltage | less than 1 volt |
| Reset Time | less than 1 second |
| Alarm Indicator | LED continuously emitting red light |
| Remote Output | 25 mA max., diode gate |
| Operating Temperature | -10°C to 50°C |
| Permissible Current | 80mA maximum |
| Humidity | 0 to 95% RH, no condensation or icing |
| Alarm Contact |